elm_config: Password mode change should reflect on already running applications.
ClosedPublic

Authored by shilpasingh on May 26 2017, 7:02 AM.

Details

Summary

When password mode is changed, the change has to reflect on already running
apps as well. config_sub_apply will not be called for an already running app.

Test Plan
  1. 2 running process
  2. Change the config value of password last show in one process
  3. Check whether the change has reflected in previous process.

Signed-off By: Shilpa Singh<shilpa.singh@samsung.com>

Diff Detail

Repository
rEFL core/efl
Lint
Automatic diff as part of commit; lint not applicable.
Unit
Automatic diff as part of commit; unit tests not applicable.
shilpasingh created this revision.May 26 2017, 7:02 AM
cedric accepted this revision.Jun 5 2017, 1:45 PM
This revision is now accepted and ready to land.Jun 5 2017, 1:45 PM
This revision was automatically updated to reflect the committed changes.